Python errors
The exceptions methods raise. The Python reference lists every group. Each page opens with its main classes, then the other classes, the dictionaries (TypedDict) and the type aliases, in stub order.
BacnetError
Section titled “BacnetError”class BacnetError(Exception)
Base exception for all BACnet errors.
BacnetProtocolError
Section titled “BacnetProtocolError”class BacnetProtocolError(BacnetError)
Raised on BACnet protocol-level errors (Error PDU).
Some services answer with a structured error body that adds fields to the class and code. Each such attribute is None unless the device’s error carried it.
Attributes:
error_class: The BACnet error class, an ErrorClass member
(an int equal to the wire value, #1816).
error_code: The BACnet error code, an ErrorCode member.
first_failed_element_number: For an AddListElement or
RemoveListElement ChangeList-Error, or a CreateObject-Error, the
position (from 1) of the list element or initial value that
failed, or 0 when the request failed for another reason. A
server’s write_property_local of a list whose object refuses one
element sets it to that element’s position in the list written.
first_failed_write_attempt: For a WritePropertyMultiple-Error, the
object, property and index of the first write that failed.
first_failed_subscription: For a SubscribeCOVPropertyMultiple-Error
about one COV reference, its object, property and index. None for
a general failure of the request.
vendor_id: For a ConfirmedPrivateTransfer-Error, the vendor of the
private service.
service_number: For a ConfirmedPrivateTransfer-Error, the private
service number.
error_parameters: For a ConfirmedPrivateTransfer-Error, the encoded
vendor-defined error parameters, when the device sent any.
vt_session_identifiers: For a VT-Close error that lists them, the
local identifiers of the VT sessions that could not be closed.
Attributes:
error_class: ErrorClasserror_code: ErrorCodefirst_failed_element_number: Optional[int]first_failed_write_attempt: Optional[ObjectPropertyReference]first_failed_subscription: Optional[ObjectPropertyReference]vendor_id: Optional[int]service_number: Optional[int]error_parameters: Optional[bytes]vt_session_identifiers: Optional[list[int]]
BacnetTimeoutError
Section titled “BacnetTimeoutError”class BacnetTimeoutError(BacnetError)
Raised when a BACnet operation times out.
BacnetRejectError
Section titled “BacnetRejectError”class BacnetRejectError(BacnetError)
Raised when a BACnet request is rejected.
Attributes:
reason: The reject reason, a RejectReason member (an int equal
to the wire value, #1816).
Attributes:
reason: RejectReason
BacnetAbortError
Section titled “BacnetAbortError”class BacnetAbortError(BacnetError)
Raised when a BACnet transaction is aborted.
Attributes:
reason: The abort reason, an AbortReason member (an int equal
to the wire value, #1816).
Attributes:
reason: AbortReason
BacnetLogNotAdvancingError
Section titled “BacnetLogNotAdvancingError”class BacnetLogNotAdvancingError(BacnetError)
Raised when a paged log read can’t advance (#1530).
The device answered a page by sequence number with records from before the one asked for, as bacnet-stack 1.6.1 does past its sequence wrap, or with none where its record counts say it holds that record. Read the log by position instead.
Attributes: requested: The sequence number asked for. returned: What the device numbered the first record it sent; None when it sent none.
Attributes:
requested: intreturned: int | None
BacnetReadRangeViolationError
Section titled “BacnetReadRangeViolationError”class BacnetReadRangeViolationError(BacnetError)
Raised when a strict read_range refuses an answer that breaks a
ReadRange rule (#1531). Read again with validation="lenient" to keep
the answer and the rules it broke.
Attributes:
rule: The rule broken, in snake case, such as
"zero_first_sequence_number".
Attributes:
rule: str
BacnetBvlcNakError
Section titled “BacnetBvlcNakError”class BacnetBvlcNakError(BacnetError)
Raised when a BBMD answers a management request (read_bdt and
its siblings, #1841) with a BVLC-Result NAK. No reply raises
BacnetTimeoutError instead, so a refusal and silence never share a
class.
Attributes: result_code: The BVLC result code it sent, such as 0x0010 (Write-BDT refused), 0x0030 (registration refused) or 0x0050 (delete refused).
Attributes:
result_code: int
BacnetBvlcUnexpectedResponseError
Section titled “BacnetBvlcUnexpectedResponseError”class BacnetBvlcUnexpectedResponseError(BacnetError)
Raised when a management request (read_bdt and its siblings,
#1841) is answered by a BVLC message it doesn’t take, such as a success
result to a table read.
Attributes: expected: The BVLC function code the request takes as its answer. got: The BVLC function code that came.
Attributes:
expected: intgot: int
BacnetTransportError
Section titled “BacnetTransportError”class BacnetTransportError(BacnetError, OSError)
Raised when a transport socket or I/O operation fails.
Covers a failed bind or listen (B/IP, B/IPv6, ScHub.start), a refused
or failed dial, and other socket errors. It is also an OSError:
errno is the operating system’s code when it reported one, else the
code for the failure’s kind (for example errno.EADDRINUSE), else
None; strerror is the message. except OSError and
except BacnetError both catch it. Unlike a bare OSError it is
not narrowed to ConnectionRefusedError and the like, so test
errno.
Attributes:
errno: int | Nonestrerror: str | Nonesc_untrusted_peer: ScUntrustedPeerInfo | None: Untrusted certificate evidence from the actual failed outbound TLS attempt. None when unavailable at the verification observation point. This is not an authenticated peer or a history of background reconnect failures.
BacnetRouterCloseError
Section titled “BacnetRouterCloseError”class BacnetRouterCloseError(BacnetError)
A settled cleanup failure. The router retains it and prevents restart.
Attributes:
failures: tuple[RouterCleanupFailure, ...]
ObjectPropertyReference
Section titled “ObjectPropertyReference”class ObjectPropertyReference(TypedDict)
The object, property and array index a structured error names.
Keys:
object_identifier: ObjectIdentifierproperty_identifier: PropertyIdentifierproperty_array_index: int | None
Release v0.15.0 ·Build and integrate. Pre-1.0 APIs; partial conformance.Support & limitations