Support status and evidence

Rusty BACnet is pre-1.0, with changing APIs and partial conformance coverage. Neither the release nor current development makes a BTL certification or full BACnet conformance claim.

The installation and local tutorials describe v0.11.0. The development section describes unreleased source, including shared endpoints, current SC requirements and local Network Number controls. A checkout may still report version 0.11.0; use its commit to identify behavior.

Standalone client, full server, shared endpoint and language binding are different surfaces. The shared endpoint’s bounded responder does not acquire the full server’s service set. Use the current transport matrix to choose a starting point, then follow its evidence links.

The current machine-readable conformance ledger owns clause status, notes and test links. The support summary, detailed ledger, draft PICS and BIBBs are generated views. This site helps readers navigate those records; it does not maintain a second support-status database.

For released behavior, read the v0.11 ledger. Current evidence must not be projected backwards onto a release artifact.

Result Useful evidence Still separate
Build or cross-compile passes Selected code compiles on that target Runtime behavior and native-library availability
Unit or simulated transport tests pass Exercised state transitions and failure cases Actual sockets, frames or physical timing
Loopback or isolated wire tests pass Captured framing and the tested owner/lifecycle Building-network interoperability and every platform
Installed Python tests pass The tested interpreter and native artifact work together Other wheels, interpreters and free-threaded builds
A ledger row has scoped evidence The stated clause behavior and controls Complete object/profile conformance or BTL listing

A screenshot, test count or single-device demonstration does not establish all-device interoperability or fitness for an operating building. No green badge replaces the stated limits. External ignored fixtures, hardware tests and ordinary CI have different execution requirements.

Start with troubleshooting for release tasks or the relevant development guide. Open a GitHub issue with revision/artifact, transport, feature set, platform, minimal reproduction and sanitized evidence. Include the exact conflicting documentation link.

Never attach private keys, customer identifiers or unredacted operational captures. Use the project’s security-reporting guidance for sensitive findings.