Configure current BACnet/SC
Current development / BACnet/SC setup
Current development · intentional changes from v0.11.0. For a released executable or package, use the v0.11 SC guide. The configuration below requires a current source build.
Prepare identities and credentials before connecting
Section titled “Prepare identities and credentials before connecting”Obtain these from the installation owner:
- The hub’s
wss://URL and the CA PEM used to verify it, including the expected hostname. - This node’s operational certificate and matching private key.
- A nonreserved local VMAC and a nonzero 16-byte device UUID, distinct from other devices.
- A known remote VMAC, object and property for a bounded initial read.
The caller provisions and durably stores the device UUID before first deployment, then loads the same identity across restarts. Do not generate a new UUID in startup code. Distinct devices must not share it; the hub’s same-UUID replacement behavior is intentional. Credentials and UUIDs are different roles: a syntactically valid UUID does not establish certificate ownership.
Connect with the current CLI
Section titled “Connect with the current CLI”From the current checkout, build without adding packet capture:
cargo install --path crates/bacnet-cli --locked --features sc-tlsAfter substituting your approved paths and identities:
bacnet --sc \ --sc-url wss://hub.example.com/bacnet \ --sc-ca site-ca.pem \ --sc-cert node-cert.pem \ --sc-key node-key.pem \ --sc-vmac 22:01:02:03:04:05 \ --sc-device-uuid 00112233-4455-6677-8899-aabbccddeeff \ read 00:01:02:03:04:05 ai:1 pv--sc-vmac identifies the local node; the final VMAC identifies the remote target. Current CLI trust requires --sc-ca: there is no system-root fallback. The read sends traffic to the named peer and does not perform discovery. Check the CLI transport reference for exact parser and startup failures.
Use the same prerequisites in Python and Rust
Section titled “Use the same prerequisites in Python and Rust”Python BACnetClient and BACnetServer with transport="sc" require nonempty sc_ca_cert, sc_client_cert, sc_client_key and keyword-only sc_device_uuid. Load the latter as 16 bytes from caller-owned durable storage. Missing or invalid identity/credential presence fails construction; file loading and TLS configuration happen at async startup. A trusted hub’s verification policy remains a separate fact.
The Python credential example and UUID migration are the signature authority. Local TLS configuration errors can be repaired at the same paths and retried within the documented boundary; this does not promise rollback after every later peer/dial failure.
Rust uses ScNodeTlsConfig and the transport’s configured device identity. Raw ScTransport::new(ws, vmac) is initially unconfigured; set a valid UUID before start. Because the caller can dial ws first, transport validation cannot undo that earlier connection. A shared endpoint uses ScEndpointBuilder with a caller-dialed TLS WebSocket; see shared endpoints.
Diagnose the stage that failed
Section titled “Diagnose the stage that failed”| Stage | Useful check |
|---|---|
| Local configuration | CA/certificate/key file readability and PEM validity, matching key, required UUID and VMAC |
| TLS connection | URL, hostname, certificate validity and issuer trust; operational credentials on both peers |
| SC Connect | Nonzero peer UUID and nonzero advertised limits; hub admission/replacement policy |
| BACnet request | Remote VMAC, requested object/property, request limits and response/error |
| Shutdown | Await the owning client/server/session cleanup; separately stop and join any caller-owned direct listener |
Current zero-limit rejection is a bounded local policy, not a claim that all positive limit combinations satisfy the full Standard. TLS 1.3 and explicit node credentials are local policy; successful connection does not prove that an arbitrary remote hub requested and verified the node certificate.
Keep transport identity separate from operation authority
Section titled “Keep transport identity separate from operation authority”Accepted direct TLS connections can carry a verified leaf identity and original-socket response authority in the native Rust path. A Hub-relayed NPDU does not become an authenticated originating leaf. Outgoing client transactions retain their documented correlation/routing rules, not a universal same-leaf continuity guarantee. Python does not expose a direct-listener entry point or a principal authorizer.
Passive Number replies, including replies to direct queries, use the Hub broadcast path. These controls do not add configured SC Network Port authority or control-origin authorization. Keep application mutation authorization distinct from TLS trust.
Next steps
Section titled “Next steps”Current SC Rust contracts · Transport evidence · Network Number controls
Release v0.11.0 ·Current development. Follow the scope named on each page. Pre-1.0 APIs; partial conformance.Support & limitations