Architecture

This page is for an engineer deciding whether to embed the Open Control Engine in a product. It answers four questions: what the layers are, where the seam between them falls, what each of the 17 crates owns, and what this engine will never do for you.

The product contract owns the aggregate requirement/evidence map and delegates domain semantics without turning future acceptance outcomes into current behavior.

The organising idea: the CDL §7.17 non-computational seam

CDL §7.17 states that point lists, trends, display units, tags, and all Brick / Haystack / ASHRAE 223P semantics do not affect the computation of a control signal. That is the cleanest seam available in this problem domain, and the engine is built along it rather than around it.

Above the seam sits an execution core: a small, deterministic, in-memory dataflow machine that sees only blocks, typed connections, and values. This is the hot path, and it has zero dependency on any database.

Below it sits storage behind a trait. Everything the evaluator must not read — equipment topology, points, instance structure, parameters, trends, semantic triples — plus durable persistence is reached only through the oce-store port traits (crates/oce-store/src/lib.rs:580). The library ships no first-party database. Durable or queryable backends are app-side adapters behind the port, with an in-memory default (oce-store-mem) so that a downstream project can embed the engine for load → flatten → validate → schedule → prepare frame → execute frame with no database at all.

The seam also fixes where responsibility for input quality lives: the host supplies every typed boundary input exactly once. Missing values refuse; Store samples and prior values cannot fill gaps. Typed completeness does not establish sensor quality or freshness, so the engine still implements no fail-safe policy of its own. Staleness limits, fault reactions, and safe-state fallback belong to the host layer above it; see host-responsibilities.md.

The pipeline: build once, tick many

Parsing, elaboration, conformance rejection, algebraic-loop rejection, and topological sorting all run once per load. What survives is a frozen schedule over flat arrays, and TICK walks it: no graph traversal, no hashing, no store access in the graph evaluator.

The current runtime is the fixed HostTick v1 execution profile: every successful frame execution evaluates this schedule once and advances state once, including at a repeated timestamp. It does not implement Modelica same-time event iteration for CDL.Logical.Pre.

Embeddability posture

The engine is, by design:

  • Library-only. No main, no [[bin]], no daemon, no server, no network listener — verified by the absence of any binary target or std::net use in crates/. The host owns process lifecycle, transport, TLS, authN/Z, multi-tenancy, off-host durability, and metrics export.
  • Synchronous and in-process. Every public method is a blocking synchronous call, and no async runtime is pulled at any layer. The check is the dependency set below, not a promise.
  • #![forbid(unsafe_code)] in all 17 crates, belt and braces: each crates/*/src/lib.rs carries the crate attribute, and the workspace sets unsafe_code = "forbid" under [workspace.lints.rust] (Cargo.toml:49).
  • Edition 2024, resolver = "3".

The whole external dependency surface on the embed path is four crates: serde, serde_json, thiserror, and libm. Two more — regex and ryu — exist only inside oce-conformance, which nothing else in the workspace depends on, so a host embedding oce-api never links them.

Two Rust versions, and they are not the same number

These are different values on purpose, and conflating them has already cost this repo one reverted change (PR #209).

ValueWhereWhat it means to you
MSRV1.97.0Cargo.toml:42 (rust-version)The floor a consumer needs. Build the engine with any toolchain at or above this.
Pin1.97.1rust-toolchain.toml (channel)What CI and local development actually build with, so the two agree exactly.

The MSRV cannot be raised to match the pin casually: the release gate’s cargo public-api surface checks shell out to a pinned nightly that identifies as rustc 1.97.0-nightly, and Cargo enforces rust-version against it. Cargo.toml carries the full explanation inline at the declaration.

Determinism, and the two allocation carve-outs

The tick is deterministic: a frozen, topologically-sorted schedule evaluated over flat arrays, with no graph walks, no hashing, and no store access in the graph evaluator. Two carve-outs, both real, both stated here rather than in a footnote.

The evaluator is not allocation-free for every block. The schedule and state arrays are preallocated and the gather scratch is reused, so most blocks tick without allocating. CDL.Reals.Sort uses fixed stack buffers through nin = 64 (SORT_STACK_WIDTH, crates/oce-blocks/src/reals_matrix.rs:340), then falls back to two heap-allocated vectors for wider inputs. CDL.Reals.Log and CDL.Reals.Log10 use static warning messages, so warning emission allocates nothing block-side — but a diagnostic sink may still allocate when it records an event, including the completed-frame warning collector. Size a host loop against the blocks and the diagnostic sink your sequence actually uses, not against a blanket guarantee.

Frame execution is Store-free. Preparation owns the complete typed observations and resolved targets; execution consumes the plan and produces an owned receipt. Their structural allocation budget scales with inputs, fan-out, boundary outputs and emitted warnings. It is not zero allocation or a whole-state clone. Load-time Store recovery, save and handle-cardinality validation remain.

Whether a block tick allocates on the evaluator thread is gated per-PR, registry-wide and with a positive control, by crates/oce-blocks/tests/tick_allocation_census.rs. No current block delegates work to a worker thread; such an implementation would need a companion guard for worker allocation. The facade’s corpus-wide Store guard is crates/oce-api/tests/frame_purity.rs; frame allocation formulas are checked by frame_observations.rs. Throughput figures live in docs/benchmarks.md, recorded per run with the commit and host that produced them, because nothing re-measures them in CI.

The crate map

Seventeen crates. The dependency direction is acyclic and organized around the seam above. Their responsibilities below do not imply equal support or publication status. The normative package, feature, and publication policy classifies all 17 and separates host support from registry dependency closure.

Execution core (Group A — no store, no database):

CrateResponsibility
oce-modelPure value/connector/instance/connection types; the Value enum (Real/Integer/Boolean/String/Enum) and the flattened model graph — the shared executable truth.
oce-exprThe CDL §7.7.2 binding-expression parser and evaluator (closed-world, pure). Bounded on structure: input deeper than MAX_NESTING_DEPTH (64) or wider than MAX_EXPR_NODES (4096) is a typed error, not a stack overflow (crates/oce-expr/src/lib.rs:125, :132).
oce-blocksThe Block trait and the native CDL elementary-block library, publicly enumerable at runtime via catalog() (crates/oce-blocks/src/catalog.rs:155) with ports, parameter rules, and honest parameter defaults per class.
oce-flattenReserved seam; an identity passthrough today. oce-cxf owns lowering because CXF arrives pre-flattened, so flatten() returns the model unchanged (crates/oce-flatten/src/lib.rs:53). Full .mo flattening is deferred. It is a publishable implementation dependency on the oce-api path, not an independently supported package.
oce-validateLoader conformance: subset rejection, single-assignment, type and attribute unification, parameter rules.
oce-graphThe deterministic scheduler and executor: direct-feedthrough DAG, algebraic-loop rejection, its own Kahn topological sort, the tick loop.
oce-cxfCXF (Control eXchange Format) JSON-LD ↔ model graph, both directions. Composite nesting is bounded at 64. Boundary lowering is iterative and separately bounded at 64 non-top isConnectedTo hops per path, 65,536 target examinations, and 8 MiB of aggregate target-IRI bytes per document. The accept/reject contract is written out in cxf-composite-subset.md.
oce-semanticsActive effective-point metadata resolver. Derives metadata from connector attributes, direction, value type and defaults; this is unrelated to the removed semantic-template loader. Raw __cdl / __CDL annotation parsing remains deferred. It stays a wired, publishable oce-api implementation dependency, not an independently supported API.
oce-diagThe shared diagnostic vocabulary (Severity / DiagCode / Diagnostic) across the ingest path. Zero dependencies.

Storage ports (the seam — traits only, no database types):

CrateResponsibility
oce-storeThe seam. The ModelStore / PointStore / SemanticStore / Durable traits plus DTOs, unified by the Store supertrait. No database types.
oce-store-memThe default in-memory backend, so the engine runs with no database. It is an unconditional publishable implementation dependency, not independently supported host surface.
oce-reference-wal-adapterVerification-only, publish = false. A std::fs WAL and atomic-snapshot adapter that exists to prove the frozen seam can carry real durability without a first-party database. Not a supported backend.

Verification, externals, and the host facade:

CrateResponsibility
oce-conformanceVerification-only, publish = false. The funnel-style tolerance-band and golden-trace conformance harness. Standalone: no other crate depends on it. Read TESTING.md for what it does and does not check.
oce-blessTest-support only, publish = false. The single definition of the repo’s environment-variable truthiness policy, so golden-regeneration switches cannot drift apart across crates.
oce-extensionExperimental/reserved, publish = false; nothing consumes it. The intended role is the FMI / extension-block boundary. No crate depends on it, the CXF resolver has no extension-block branch (an unknown class is a hard ClassNotFound), and DiagCode::MissingFmuPath (crates/oce-diag/src/lib.rs:167) is declared but never constructed. Do not plan FMI integration against this crate.
oce-docsReserved panic-only seam, publish = false. The sequence-spec and point-list export surface is declared; point_list_html panics with unimplemented! (crates/oce-docs/src/lib.rs:17). Nothing depends on it.
oce-apiThe primary embeddable host facade: Engine<S: Store = MemStore>, spanning load, complete-frame preparation/execution, parameters, IO inventory, latest-state non-receipt reads (get_output/watch), CXF export with content id, and a read-only topology view. The actively supported oce-blocks::catalog() metadata API is a separate companion surface; see the public surface contract.

Four of those — oce-flatten, oce-semantics, oce-extension, oce-docs — are reserved seams rather than working components. They are named here so that nobody plans a feature against a crate that does nothing yet.

The legacy mem compatibility spelling

oce-api declares default = ["mem"], but mem = [] gates nothing and oce-store-mem is an unconditional dependency, so disabling default features does not remove the in-memory backend. The flag is retained temporarily as a truthful legacy no-op while downstream manifests migrate. What actually makes MemStore the default is the type parameter in Engine<S: Store = MemStore>. To use a different backend, name it: Engine<MyAdapter>. The complete supported matrix and its mechanical closure guard are in the package policy.

What this engine will never do

Each of these is a design commitment, not a gap waiting to be closed.

  • No first-party database. Persistence lives behind the oce-store port, authored app-side.
  • No daemon, no server, no network listener. It is a library; the host owns the process.
  • No async runtime at any layer, pulled by any crate.
  • No fail-safe policy of its own. It does not decide what a stale sample means, what a faulted point should do, or what safe state looks like for your equipment. Those decisions are yours, and they are enumerated in host-responsibilities.md.

For what the engine has and has not been verified against — including the global report tiers that are not wired — see TESTING.md and the verification section of the README.