Benchmarks

Measured tick throughput for the Open Control Engine, recorded per run with the commit, host and method that produced it.

Read this first

Historical throughput numbers are not gated. Nothing in CI or in .agents/gate.sh re-measures those runs, so they are a record of what was observed, not a promise about HEAD. A performance figure that no test enforces drifts silently — the same failure mode that got a git SHA deleted from every provenance record in PR #204, and the reason the numbers live here rather than in README.md, where they would be read as a standing claim.

Treat a run below as evidence about that commit on that host. To make a claim about a different commit, measure the current contract with the compiled harness described below. The retired execution profiles are not interchangeable with complete-frame work.

The complete-frame harness below now runs structural allocation assertions and emits non-gating latency observations. Historical throughput runs retain their original method and limits.

Complete-frame observations

2026-09-19, implementation working tree based on 64e7ba83ff78a6d07750502d0f3f037b8b39f519. Apple M5, aarch64-apple-darwin, macOS 27.0 (26A5425a), Rust 1.97.1. Default features, locked dependencies; dev/debug and release (workspace thin LTO, one codegen unit). These are local observations, not hosted x86_64/arm64 qualification, equipment cadence or universal speed claims.

The historical version of frame_observations.rs used five representative fixtures. Load was excluded. Constant schema-valid synthetic inputs were staged once for legacy tick; native frames supply the same complete values each time. Equal model time 0.0 deliberately tests repeat transitions. After 64 warmup calls, five 2,048-call batch means are measured, alternating commit/tick order. Commit timing excludes preparation and outer plan-batch allocation but includes plan and result destruction. End-to-end preparation+commit is also reported. Legacy tick includes its MemStore snapshot where inputs are bound, uses no-op diagnostics and produces no retained frame, so this is a cost comparison between different contracts, not an equivalent-work speedup. Only this test was scheduled during explicit measurements; other machine activity was not controlled.

Median of five batch means, nanoseconds per call:

CaseDebug tickDebug commitDebug prepare+commitRelease tickRelease commitRelease prepare+commit
Add arithmetic2113901,3573476171
Sampled delay3455181,4734279158
Zero-input Pre feedback282471533356869
213-block G36 controller18,63117,71426,5502,5782,5573,246
Assert, zero boundary outputs2144669932879126

Commit batch-mean ranges (debug / release ns): arithmetic 388–399 / 63–78; delay 488–526 / 78–86; feedback 419–473 / 63–69; controller 17,625–17,951 / 2,538–2,637; assertion 453–475 / 72–91. These short samples expose host drift, not tail latency or confidence intervals. No timing value or ratio is an assertion; the functional determinism tests are separate.

The historical debug/release harness asserted the exact allocation formula over 128 preparation+commit repetitions per fixture and zero outstanding allocations after drop, with a 1,024-byte positive control. It counts the synchronous thread only. N is logical inputs, T fan-out targets, B boundary outputs and D emitted warnings (these cases have at most one):

CaseN / T / B / DPreparation allocations / bytesCommit allocations / bytes
Add2 / 2 / 1 / 04 / 1202 / 66
Delay2 / 2 / 1 / 04 / 1202 / 59
Pre0 / 0 / 2 / 00 / 03 / 114
Controller14 / 43 / 10 / 016 / 95611 / 1,136
Assert1 / 2 / 0 / 13 / 643 / 262

Preparation uses N+2 buffers for nonempty N. Historical commit capture used B+1 buffers for nonempty B, with B * size_of::<(String, Value)>() + sum(path_bytes) bytes; zero B allocates none. Each warning copies its source/message and grows a Vec geometrically (one warning uses four event slots). Value cloning preserves bits and shares immutable String payloads. This budget is structural: no shadow RunState, whole-engine copy or rollback. Existing evaluator allocations, notably wide Sort, remain a separate baseline cost; this fixture census does not erase them.

The shared evaluation-core extraction based on 8ea3e8f38d580868179bfa985b443b71ca3b86c1 re-ran this exact census in debug and release on aarch64-apple-darwin/Rust 1.97.1: all five preparation/commit counts and byte budgets above remain unchanged. The latency test also ran, but these observations are not a speed gate or a before/after performance claim. The historical timing table above is not re-blessed. The frame-only contraction removes the legacy comparison; the current harness measures commit and preparation-plus-commit only, retaining the allocation formula checks. All accepted frames now retain warnings. No current latency claim is inferred from the historical tick columns.

Canonical replay delivery additionally retains the accepted inputs in every completed receipt: N canonical path buffers plus one N-pair vector for nonempty N, costing N * size_of::<(String, Value)>() + sum(input_path_bytes). Prepared Values move into this vector; there is no second value-byte copy. Placement capture scans block classes under the state policy. The current harness asserts these added counts/bytes over the same 128 repetitions with zero retained allocations after drop. The historical table above is not a current total or latency prediction. Record encoding/decoding is separate opt-in work; the replay contract documents its caps and streamed-host allocation evidence, not a speed claim.

Run observations explicitly with --success-output immediate --test-threads 1 on the focused frame_observations nextest binary. It is also included in the existing oce-api matrix test set; normal success-output suppression hides passing timing logs, but allocation checks still execute. Use --locked --profile ci --no-tests=fail for debug and --locked --profile ci-release --cargo-profile release --no-tests=fail for release. The full repository gate remains .agents/gate.sh, not this measurement selection.

What the historical throughput runs measured

The now-retired steady-state Engine::tick() on real G36 fixtures, through the then-public facade: Engine::in_memory() → load_cxf() → tick().

  • Load is excluded from the tick figure and reported separately. Loading happens once; ticking happens forever, so blending them would flatter the result and describe neither.
  • Ticks are run for a fixed wall-clock window after a warmup, so first-touch page faults and any lazily initialised state land in the warmup rather than the measurement.
  • The clock is read in batches, so the timing call is not itself the workload.
  • Time advances monotonically. The engine rejects time regression, so t only ever increases across warmup and measurement.

What is not measured

Stated explicitly, because the gap between these and the numbers below is where a wrong conclusion would come from.

  • Load / parse / resolve throughput beyond the single load_ms column.
  • Tail latency. These are means over millions of ticks. For equipment control the tail usually matters more than the mean, and one property that governs it — whether the evaluator thread allocates during a block tick — is gated separately and much more strictly, by crates/oce-blocks/tests/tick_allocation_census.rs (registry-wide, with a positive control), which runs per-PR. Current facade frame allocation and Store-noninterference checks also run per-PR in frame_observations.rs and frame_purity.rs. Historical throughput is not gated.
  • Multi-core or concurrent engines. Single engine, single thread.
  • Any architecture other than the one in the run header. CI runs a determinism matrix across x86_64 and arm64 precisely because one machine does not speak for both.
  • Store-backed input staging under a real durable store. Runs below use the in-memory store.

Runs

2026-07-30 · b5b19e7 · Apple M5 (10 cores) · rustc 1.95.0 · macOS 26.6 · --release

Warmup 20,000 ticks · 2.0 s measurement window · dt = 1.0 simulated second per tick.

fixtureCDL class refsns/tickticks/sec
cooling_only_controller2222,508398,801
multizone_vav_relief_fan_group2282,706369,558
multizone_vav_supply_fan717551,325,349
ahu_economizer121417,095,155
vav_single_zone81446,932,518

Repeated back to back; the two runs agreed within ~2% on the large fixtures and ~6% on the smallest. Measured on an otherwise idle machine — an earlier attempt taken while a parallel build was running produced numbers that were not reproducible, which is why the method above insists on it.

Load, same commit and host — 60 iterations per fixture

Reported as first / median / min in one process, because a single first-call figure carries process-start and page-cache cost.

fixtureKiBfirst msmedian msmin msfirst÷medMiB/s at median
cooling_only_controller4097.842.622.483.0×154
multizone_vav_relief_fan_group3662.552.122.021.2×169
multizone_vav_supply_fan1120.890.680.661.3×159
ahu_economizer160.140.110.101.3×144
vav_single_zone140.110.090.081.3×150

These numbers were measured before #230, which added a working-clone @context expansion pass to ingest; load cost moved roughly +9–12% there, tick cost not at all.

Correction to an earlier revision of this file. It reported 11.0 ms for cooling_only_controller and placed the “runs agreed within ~2%” sentence where it read as covering that column too. Both were wrong. That figure was a single first call in a cold process — it is the first fixture measured, so it absorbed process start and page-cache misses. Measured properly it is 2.62 ms, a 4.2× overstatement. A second process invocation shows the same fixture’s first/median ratio collapse from 3.0× to 1.3× once the page cache is warm, while every other fixture sat at 1.1–1.5× in both runs. The tick figures above were unaffected: they were always taken after a 20,000-tick warmup, which is exactly the discipline the load column lacked.

Observation — load throughput is flat. 144–169 MiB/s across a 29× size range, through the whole load_cxf pipeline: import_cxf (JSON-LD parse and resolve to a flat ground ModelGraph), flatten, §7.10 attribute unification, structural validation, then the build tail (registry, schedule, state, outputs, io, params, store recovery). That is not a JSON parse, so a plain parser MB/s intuition does not apply. The measured revision re-ran pure validation in the build tail. Current load_cxf validates once before entering build_validated_model_in_memory (crates/oce-api/src/engine.rs:231-244), so this historical table includes work the current path no longer performs.

Observation — cost is linear in block count. Across a 28× size range the per-block cost holds at roughly 11 ns (11.3 / 11.9 / 10.6 / 11.8 ns for the four largest). vav_single_zone is the exception at ~18 ns per block, and it is the expected one: at 8 blocks the fixed per-tick overhead (finite/monotonic time checks, output refresh) stops being amortised. No superlinear term is visible, so a sequence twice the size costs about twice as much.

Caveat on “CDL class refs”. That column counts CDL type references in the fixture’s JSON-LD. It is a proxy for scheduled block count, not the count itself, so the per-block figures are indicative rather than exact. The linearity across 28× is the load-bearing part and does not depend on the proxy being tight.

In deployment terms. cooling_only_controller is the largest fixture document in the corpus (409 KiB; 213 blocks and 268 connections after import) and ticks in ~2.5 µs. Building control sequences run at a 1 Hz cadence or slower.

Correction, 2026-07-31. This paragraph previously called it “the largest sequence in the fixture corpus (213 instances, 377 edges)”. Both halves were wrong: relief_fan_group imports to 226 blocks, more than this fixture’s 213 (pinned at crates/oce-cxf/tests/resolve_g36_relief_fan_group.rs:145-146), and 377 was the pre-import isConnectedTo count, not the 268 connections the tick loop actually runs. The measured timing above is unchanged and was not re-run — only the description of what was measured is corrected.

Reproducing a run

Use the repository’s compiled frame_observations nextest binary for current measurements, with the focused settings above. It submits a complete frame on every iteration and separately reports commit-only and preparation-plus-commit cost. There is no sparse staging or implicit hold-last benchmark profile. Historical tables retain the method and limits of their recorded revisions; they are not predictions for the frame-only facade. No older timing table has been regenerated.

Run it on an idle machine, and run it at least twice — a figure that does not reproduce is not a measurement.

To measure load rather than ticks, loop the Engine::in_memory() + load_cxf pair on its own (60 iterations is plenty) and report first / median / min, not a single call. The first call in a cold process absorbs process start and page-cache misses; on the largest fixture that inflated the figure by 3× and produced the erroneous 11.0 ms corrected above. Reporting only a median hides the cold cost from anyone who cares about startup, and reporting only a first call is simply wrong — report both. Time Engine::in_memory() inside the measured region and let the engine drop outside it, since teardown is not part of load.

Adding a run

Append a new ### <date> · <short SHA> · <host> · <toolchain> · <profile> section above the previous ones, newest first. Never edit an older run to match a newer one: the value of this file is the trend, and a rewritten history has no trend in it. If a run regresses, record it and say so — that is the entire point of keeping the record.