Pinned strict-bit signal evidence

Status and claim boundary

Accepted native Linux corpus evidence: receipt data identifies the native matrix from run 37382761120, with an exact, reviewed 35-file selected source boundary covering checker/admission/comparison/workflow/direct formula/harness and supporting sources. The ordinary retained-qualification test requires every enumerated path and digest alongside the eight raw captures and reference/input inventory. This is not a complete compiled dependency closure or proof of current whole execution semantics.

The machine-readable corpus is the authoritative inventory of the 21 existing aligned-tolerance Real signal paths. It contains 161 samples: 101 finite (including 18 signed-zero samples), 52 NaNs and 8 signed infinities. corpus.json retains the original macOS aarch64 debug observation. Separately, the eight qualified native Linux captures are accepted permanent evidence for Linux x86_64/aarch64 × debug/release, two independent process runs per cell. Every run contains all 21 signals and 161 samples, with zero mismatches against the unchanged Tier-A references and across cells under the exact comparator. Every first/repeat pair is byte-identical, including NaN payloads. PC-037 is CURRENT only for this bounded observed-output result. The four suites use exact comparison for these 21 Linux Real signal cases; no Tier-A golden, comparison tolerance or bound source was changed for admission.

The local macOS debug/release tests still compare against the original observation. This is a regression observation, not macOS qualification. macOS-arm64 remains explicitly conservative/unqualified until M06-PR02; macOS and all other unqualified targets keep atoly=rtoly=ltoly=1e-12 in the four suites, with exact time/discrete comparison.

Accepted native receipt

  • GitHub Actions run 37382761120 produced all eight native captures with the selected 35-file map and a successful cross-cell comparison. It was collected for the workspace 0.2.0 version bump (GitHub #333), whose Cargo.toml and Cargo.lock bytes are bound sources; no checker, workflow, math or harness source changed.
  • The run head was f8dcaeb861fa18ef4c720b6fa2963b026f3a8300. All captures preserve GitHub’s actual synthetic PR merge checkout fbae3b96b053836b916f603a0d86c53d30bce628, not the run head or a later delivery commit. Each capture binds 35 source digests, 21 signals and 161 samples.
  • rustc: 1.97.1 (8bab26f4f 2026-07-14); libm: 0.2.16; baseline repository codegen, without custom RUSTFLAGS or CARGO_ENCODED_RUSTFLAGS.
  • Uploaded assembled artifact archive digest: sha256:0c94225cc2499e577cb597d0c36cbee138fc88bb65791872f1deb5c38e6b6576.
  • Downloaded matrix.json SHA-256: 78c5efaf4881977d306fc1f7a09c51f37cf897be338558d14aee9c2313d035d9; its comparison is {"Ok":[]}. The retained test reconstructs this exact aggregate from the eight canonical capture files and verifies the digest, without storing a redundant ninth copy. Each per-cell upload (strict-bits-<runner>-<codegen>) is byte-identical to its two files in the assembled artifact.
Native cellSHA-256 of both first and repeat capture
Linux aarch64 debug6ed52dfdeaeb04d8c270943ec8bd594c7383aa5fc37cd8beff9446d675a78751
Linux aarch64 releasef97c6d8c257ab632a1685268a6a350bc46b55ebc5bd4c685b0d8b51ec9588442
Linux x86_64 debug84d66c267e71f7f5e7ac02e7050fee99cf33ffca9b18bd81389fd7144e9368b2
Linux x86_64 release81087ece58ea985d0d11cf79df78fefe7163b0180f2b8aa05d07902a5d6772d4

The collection run was intentionally not a final green CI run: at collection time the new receipt had not been admitted. Each normal cell suite failed only its required receipt-admission check (source digest changed: Cargo.lock), the cross-cell job failed only its subsequent cell-success check, and gate (light) failed the strict-qualification prerequisite. Capture and cross-cell numerical comparison succeeded; their artifacts are evidence of that bounded result, not evidence that every hosted gate passed. Data-only admission now satisfies the ordinary retained check without changing any bound source. Admission also updates the receipts.json evidence digest in the release-compatibility matrix, which binds receipt bytes but is not itself a strict-bit bound source. Final hosted gate status remains a separate delivery check.

Historical receipts

Run 35494403523 (head d57e946126af76ed58ff10cef1e35ffbb627832f, synthetic merge d16d69a49857ea9abd35a12643e83139ca5c6a6f, matrix.json SHA-256 3f6f9efe8e4f9980a790c1a0d8eba1143111a6ae9138f0d486cca841aa19b7fc) was the previous current receipt over the same 35-file boundary. Its eight captures were replaced in qualified-linux/ by the run above and remain readable in Git history; the receipt schema keeps one historical and one current entry, so it is not separately pinned.

The original Linux captures remain unchanged historical evidence, separately pinned by receipts.json.historical:

  • GitHub Actions run 35492290613 passed all four strict-bit cells and the cross-architecture/codegen job.
  • The provisional PR head was dbce73fb20ada4a3a91653bb7ad9b48fae7ee87d. All eight captures honestly record GitHub’s synthetic PR merge checkout 8a63d4a042e1ca91d5dfe7bd3fc33d194f5102bb, not that PR head or a later delivery commit.
  • rustc: 1.97.1 (8bab26f4f 2026-07-14); libm: 0.2.16; baseline repository codegen, without custom RUSTFLAGS or CARGO_ENCODED_RUSTFLAGS.
  • Uploaded assembled artifact digest: sha256:d5b21ca70517c793f46a99d5402d236e2c78494466367fa583ccef27431c31c4.
  • Downloaded matrix.json SHA-256: 12a2fbdd28c9718c0145c5055240f0b7eab3d7898bc5d1f05ed0ee09db2978ad; its comparison is {"Ok":[]}. The historical test reconstructs this exact aggregate from the eight canonical capture files and verifies that digest, avoiding a ninth duplicate of the raw data. The upload archive digest is a provenance locator, not a locally rebuilt archive.

The historical receipt test reconstructs that aggregate verbatim. Its 17-source map omitted semantic capture/comparison/admission code now required by the selected 35-file admission boundary. The otherwise successful exact-head run 35493024355 used the same smaller source map; neither replaces the current selected-boundary receipt from run 37382761120. No old raw file, Git revision, source map or candidate label is rewritten to imply those sources were captured then.

The active current-qualification test validates the admitted selected-boundary receipt and all four cells, two runs per cell, 21 signals and 161 samples per run, zero mismatches, byte-exact repeats, capture identity and aggregate integrity. It requires exactly the 35 enumerated source paths/digests and current reference, provenance, input/CXF and time inventory. The synthetic checkout SHA is not required to equal a later HEAD or exist in local history. A historical receipt cannot bypass a missing or changed entry in that selected boundary, even when raw outputs agree. This guard does not establish source identity for the rest of the compiled execution path.

libm 0.2.16 does NOT promise cross-architecture correctly rounded transcendentals; strict identity is an empirical pinned observation only. std 1.97.1 likewise does not promise deterministic transcendentals. The versioned libm documentation and Rust f64 precision contract do not justify upgrading a finite-corpus observation into an arbitrary-input guarantee.

The Tier-A generator has an independent dependency direction, enforced by the existing golden-gen firewall, but shares formulas and libm with these engine paths. Strict-bit evidence proves implementation/plumbing/pinned portability over the corpus, not mathematical correctness or arbitrary inputs. The original provenance’s wording about deterministic math is retained verbatim as historical provenance, not adopted as a library guarantee. CDL.Reals.Sqrt and G36 funnel bands are outside this inventory. Public runtime behavior, state/snapshot portability, target-bound restore policy, algorithms, dependencies and non-21 comparison regimes are unchanged.

Artifact contract

Schema 1 is UTF-8 JSON with a single header and one canonically ordered object per signal. It is capped at 128 KiB per capture and 128 samples per signal. The header pins rustc’s full version, libm, Git revision, actual native OS/architecture/codegen cell, explicit qualification limits and SHA-256 of the selected locks, toolchain, fixture definitions, harness, checker and math source files. The Git revision names the observation’s checkout HEAD; hashes separately bind the selected file bytes and generated CXF, without claiming uncommitted bytes were committed at that HEAD or binding unlisted transitive sources.

Each signal names its class, output and unique case path; reference CSV, original provenance and generated CXF digests; original operation/recurrence rule and math-library provenance; proposed Linux (at capture time) and conservative other-platform regimes; every time, oracle value and engine value; and every exact mismatch index. Input/parameter provenance is available through the bound reference CSV and generated CXF. Cases in the four existing suites are a checked projection of this inventory, not a second manually maintained list. No oracle output is generated from engine output.

Words are label:hhhhhhhhhhhhhhhh, a lowercase, exactly 16-digit raw u64 hexadecimal encoding. Labels are finite, +zero, -zero, +inf, -inf, and nan; labels are validated against bits. Raw NaN sign/payload is retained. Cross-cell exact comparison treats all NaNs as one class, as the existing driver does; finite bits (including the sign of zero), signed infinities and time bits are exact. Repeat captures within a cell compare all raw bytes, including NaN payloads. No digest-only result substitutes for raw samples.

Unknown fields, wrong pins, missing/duplicate/unordered signals, changed provenance, incomplete sample arrays, wrong labels and hidden mismatches refuse. Selected-source, lock, toolchain or inventory changes invalidate the retained contract and need deliberate evidence review/refresh. CI cannot admit checked-in observations. Capture always refuses to overwrite an existing artifact; the historical-corpus refresh switch has been removed. Reference inventory validation is intentionally separate from qualification: matching the old reference/input inventory does not admit an old source map. Review every new observation rather than blessing changed engine output as correctness.

Non-circular source binding and admission

The source-digest list enumerates exactly 35 selected files: the original locks/toolchain/build inputs, four math implementations, four suites and three harness modules; plus strict_bits.rs, strict_bits/{evidence,matrix,controls}.rs, the facade driver and its comparison module, exact and aligned comparators, CSV/config/series/masking support and conformance module wiring, model value encoding, the conformance manifest, CI workflow, nextest configuration and gate script. The inventory/control tests require exactly this set and prove that changing any selected file refuses admission even with unchanged raw samples. Specific mutations disable non-finite equality and matrix topology checking; their source changes still refuse before receipt acceptance.

This selected boundary is not the full compiled transitive facade closure. The driver executes through oce_api::Engine, but the map does not hash all oce-api, oce-cxf, registry/lowering or other transitive implementation sources. Exact equality of its 35 digests establishes equality only for those selected bytes, not current whole execution semantics or whole-executable identity. Exact-head hosted cells (x86_64 native, aarch64 QEMU-emulated) rerun the actual facade execution path per PR and catch changes under the pinned corpus’s stated exact-comparison rules. An unbound transitive source change preserving all pinned outputs does not invalidate the historical raw result; neither the receipt nor those reruns prove behavior on arbitrary inputs.

The receipt-binding order is selected source bytes → captures → assembled matrix → receipt data. The checker hashes its own source bytes, which contain no expected source or matrix digest. receipts.json is a closed, terminal data schema containing historical and optional current Git/matrix identities; it contains no executable policy and is not hashed back into captures. Current admission checks those reviewed identity values against actual raw data and current selected-source digests. Final admission changes only receipt/fixture data and documentation, not bound checker code. This avoids both a self-hash fixed point and a matrix-digest cycle; it is not a migration bypass.

The current receipt was admitted through the explicit admission test with OCE_STRICT_MATRIX_DIR naming the download. It validated the selected source entries, reference/input data and the exact aggregate before creating qualified-linux/; all eight retained files equal the downloaded bytes. The test refuses CI and replacement of an existing directory, so a refresh first removes the previous qualified-linux/ (preserved in Git history) and then admits the new download. linux/ and corpus.json remain unchanged history. A bound-source change after the native run needs another native run; receipt-only admission does not. No environment switch or historical-source exception bypasses current qualification.

CI data flow and adjudication

The native receipt above was produced on GitHub Actions, on ubuntu-latest and ubuntu-24.04-arm, by the now-disabled .github/workflows/ci.yml. The per-PR gate is now .github/workflows/pr-gate.yml on GitHub-hosted x86_64 runners, and its scoped strict-bit-matrix job runs on every development PR and every push to development (and on manual dispatch) in four cells: x86_64 natively and aarch64 cross-compiled under QEMU user-mode emulation, each in debug and release. The aarch64 cells are emulated, not native: they keep the cross-cell comparison running per PR but cannot produce admissible native aarch64 evidence. Each cell clears cached evidence, makes two independent nextest process captures at that PR’s checked-out revision (each also repeats the actual facade drive internally), compares their bytes, and runs the four suites plus inventory, strict wiring and hostile controls. Every cell runs even after an earlier one fails. CI does not retain the raw captures: they exist only in the job’s workspace and its log output.

The same job then runs the otherwise-ignored matrix test over all eight files. The checker requires exactly the four cells with first/repeat captures, matching Git and selected-source provenance, the complete signal/sample inventory, and exact oracle and cross-cell agreement. Missing data is failure, not a skipped signal. It emits matrix.json, containing all eight raw captures and signal/sample/expected/actual mismatches, alongside the input files even on a numerical disagreement; like the captures, it is not retained by CI. Success also requires every cell’s wiring and mutation controls to pass; matching output files cannot mask a failed cell test. Synthetic matrix tests exercise each signal in every cell, missing/extra/mislabeled cells, repeat drift, pin/provenance drift, signed zero and NaN class rules; synthetic fixtures are never native evidence.

One-ULP mutations of every finite reference sample, every corpus signed zero, and relevant NaN/Inf class/sign controls run through the facade driver. On Linux they also run through the actual four-suite policy selector and assert the exact signal/sample failure; comparator-only unit tests are not the sole evidence. Unmodified neighboring outputs stay green.

The successful native artifacts above are now checked in, rather than relying on a 90-day upload. The explicit, ignored admission test verifies the downloaded aggregate digest, every canonical capture, the zero-mismatch result and current selected-source equality before creating the retained directory; it refuses replacement and cannot run in CI. It copies native evidence, never local engine output. Ordinary retained validation is read-only and needs no environment opt-in. Future divergence leaves the gate red with exact mismatch bits. Adjudicate the path before any claim or regime change; no automatic downgrade, tolerance widening, bit-pattern acceptance, formula rewrite or Tier-A regeneration is authorized. A changed selected source, pin or corpus needs a new reviewed native receipt, not a rewritten historical observation or environment bypass.

The gate script runs the scoped tests in both codegen profiles locally, but cannot reproduce a cross-architecture result on one machine. The hosted matrix is separate from the existing state-artifact determinism matrix; neither substitutes for the other. The required CI OK status needs the strict-bit job’s success, so the check is not merely an optional status. A future native evidence refresh needs a native arm64 runner; changes to branch protection remain the orchestrator’s responsibility.

Downstream notice

Whole-executable exactness inherits the least-qualified contributing path, target and input domain. These 21 finite-corpus results do not qualify arbitrary compositions, arbitrary inputs or a whole executable; unqualified paths/platforms still prevent such an inherited exactness claim.

This schema is compact, inspectable input for later Open Control Sim consumption, not a Sim policy change or qualification. The supplied downstream inventory says Sim has no active oce-api dependency; its matching libm pin is context only. Sim policy adoption remains M05-PR07. No Sim checkout, source, dependency, tolerance policy or platform claim is changed here.