  "revision": 1,
  "policy": "fail-closed-no-n-minus-one",
  "candidates": {"current": {"implementation_baseline": "3a7bdf023062d5dc3f433c7e28be4cde033224bf", "implementation": {"files": 326, "sha256": "dc0eda9060464a78b9caca0bc89ee1d3fe56720ff0ae8f3bfd709f57fdd08c04"}}, "historical": {"tag": "v0.1.0", "tag_object": "7f3b614dc0e466d54cab4677ce4bb08a5bfaf033", "source": "909a8ba699e6a2fccf3de6ac0616a9e83a04060f", "kind": "historical-git-pin-not-published-not-supported-n-minus-one", "package": "0.1.0", "receipt_sha256": "483e21edadd18cc8dac264e6ef76bbe342a09c2305fbc69642ce67dce97d41c5"}},
  "current_facts": {"package": "0.2.0", "descriptor_revision": 1, "descriptor": {"oce-compatibility": "1", "catalog-schema": "1", "catalog": "catalog:1:fnv1a128:96724061ffda5d6a7cb9d4019c440892", "io-schema": "1", "value-schema": "1", "parameter-schema": "1", "execution-profile": "HostTick-v1", "execution-profile-schema": "2", "oce-api-version": "0.2.0", "export": "none"}, "domain_revisions": {"diagnostics": 1, "io": 1, "values": 1, "parameters": 1, "assertions": 2, "execution-profile": 2}, "state_format": 2, "execution_abi": 2, "replay_format": 1, "replay_exactness": "ExactBits", "placement": ["Portable", "TargetBound(arch,os)"], "strict_bit_class": "retained-21-signal-linux-x86_64-aarch64-debug-release-only", "other_targets": "unsupported-unqualified"},
  "conditions": {"accept": "current/current only, within each delegated artifact contract and host qualification; not arbitrary build equality", "strict-bit-qualification": "only the retained finite Linux corpus; other targets and whole-executable exactness remain unqualified", "unavailable-in-producer": "the named current artifact is absent; not a decoder refusal or missing older equivalent", "host-envelope-refusal-before-decode": "host rejects cross-candidate bytes before any OCE decoder, restore or execution", "unsupported-unqualified": "no support or equivalence claim even when source compiles"},
  "rows": [
    {"artifact": "package-public-api", "producer": "current", "consumer": "current", "status": "accept"},
    {"artifact": "package-public-api", "producer": "historical", "consumer": "current", "status": "unsupported-unqualified"},
    {"artifact": "package-public-api", "producer": "current", "consumer": "historical", "status": "unsupported-unqualified"},
    {"artifact": "package-public-api", "producer": "historical", "consumer": "historical", "status": "unsupported-unqualified"},
    {"artifact": "facade-catalog-schema", "producer": "current", "consumer": "current", "status": "accept"},
    {"artifact": "facade-catalog-schema", "producer": "historical", "consumer": "current", "status": "unavailable-in-producer"},
    {"artifact": "facade-catalog-schema", "producer": "current", "consumer": "historical", "status": "unsupported-unqualified"},
    {"artifact": "facade-catalog-schema", "producer": "historical", "consumer": "historical", "status": "unavailable-in-producer"},
    {"artifact": "public-descriptor", "producer": "current", "consumer": "current", "status": "accept"},
    {"artifact": "public-descriptor", "producer": "historical", "consumer": "current", "status": "unavailable-in-producer"},
    {"artifact": "public-descriptor", "producer": "current", "consumer": "historical", "status": "host-envelope-refusal-before-decode"},
    {"artifact": "public-descriptor", "producer": "historical", "consumer": "historical", "status": "unavailable-in-producer"},
    {"artifact": "diagnostics", "producer": "current", "consumer": "current", "status": "accept"},
    {"artifact": "diagnostics", "producer": "historical", "consumer": "current", "status": "unavailable-in-producer"},
    {"artifact": "diagnostics", "producer": "current", "consumer": "historical", "status": "unsupported-unqualified"},
    {"artifact": "diagnostics", "producer": "historical", "consumer": "historical", "status": "unavailable-in-producer"},
    {"artifact": "execution-profile", "producer": "current", "consumer": "current", "status": "accept"},
    {"artifact": "execution-profile", "producer": "historical", "consumer": "current", "status": "unsupported-unqualified"},
    {"artifact": "execution-profile", "producer": "current", "consumer": "historical", "status": "unsupported-unqualified"},
    {"artifact": "execution-profile", "producer": "historical", "consumer": "historical", "status": "unsupported-unqualified"},
    {"artifact": "executable-frame", "producer": "current", "consumer": "current", "status": "accept"},
    {"artifact": "executable-frame", "producer": "historical", "consumer": "current", "status": "unavailable-in-producer"},
    {"artifact": "executable-frame", "producer": "current", "consumer": "historical", "status": "unsupported-unqualified"},
    {"artifact": "executable-frame", "producer": "historical", "consumer": "historical", "status": "unavailable-in-producer"},
    {"artifact": "snapshot", "producer": "current", "consumer": "current", "status": "accept"},
    {"artifact": "snapshot", "producer": "historical", "consumer": "current", "status": "unavailable-in-producer"},
    {"artifact": "snapshot", "producer": "current", "consumer": "historical", "status": "host-envelope-refusal-before-decode"},
    {"artifact": "snapshot", "producer": "historical", "consumer": "historical", "status": "unavailable-in-producer"},
    {"artifact": "replay", "producer": "current", "consumer": "current", "status": "accept"},
    {"artifact": "replay", "producer": "historical", "consumer": "current", "status": "unavailable-in-producer"},
    {"artifact": "replay", "producer": "current", "consumer": "historical", "status": "host-envelope-refusal-before-decode"},
    {"artifact": "replay", "producer": "historical", "consumer": "historical", "status": "unavailable-in-producer"},
    {"artifact": "strict-bit-qualification", "producer": "current", "consumer": "current", "status": "accept"},
    {"artifact": "strict-bit-qualification", "producer": "historical", "consumer": "current", "status": "unavailable-in-producer"},
    {"artifact": "strict-bit-qualification", "producer": "current", "consumer": "historical", "status": "unsupported-unqualified"},
    {"artifact": "strict-bit-qualification", "producer": "historical", "consumer": "historical", "status": "unavailable-in-producer"}
  ],
  "typed_controls": {"status": "typed-refusal", "cases": {"snapshot-revision-one-not-from-v0.1.0": "EngineStateError::UnsupportedFormat { revision: 1 }", "snapshot-abi": "EngineStateError::IncompatibleExecution", "snapshot-placement": "EngineStateError::TargetDomainMismatch", "descriptor-field": "CompatibilityMismatch (exact first cause)", "replay-revision": "ReplayError::UnsupportedFormat", "replay-exactness": "ReplayError::UnsupportedExactness", "replay-descriptor": "ReplayError::DescriptorMismatch", "replay-placement": "ReplayError::TargetMismatch"}},
  "evidence": [
    {"path": "crates/oce-api/tests/public-api.txt", "sha256": "db804469b3d16c4d7388a6540204c3304ecacdb5ba55172f07d7016e8a3fb948"},
    {"path": "crates/oce-store/tests/public-api.txt", "sha256": "78cf5fdbcbd415a4ca3c521501c9c1a9ccca099551839c2fd360edc311fcbafe"},
    {"path": "crates/oce-api/tests/public_surface_contract.rs", "sha256": "60bcb691daecbf8023f8c73849266f3bfc6beae7c8c7c9e8467dfa44f44ce7a7"},
    {"path": "crates/oce-api/tests/catalog_contract.rs", "sha256": "540f0f51db866f4c9cc0ce73febf4d28339a5d9d8980d2e893f52d747f6064ba"},
    {"path": "crates/oce-api/tests/compatibility.rs", "sha256": "c0a117ee4976ab5aa1fdb23d69765ef10ddce4b9cb6a47d3caad997d4c07d9cd"},
    {"path": "crates/oce-api/tests/fixtures/compatibility.txt", "sha256": "228a70630576dd8a55cd6df649ecfcf078a076f59b43cabb5ded7d01ee78e993"},
    {"path": "crates/oce-api/tests/state_contract.rs", "sha256": "8efe8932e35c27716aa1b315cb5660e6bcf659fbca52f2148854bfaadf29092c"},
    {"path": "crates/oce-api/tests/replay.rs", "sha256": "5364c5aab1981a1076c38b24ebf2f5b1e8c32602a4aae448f9a0b3127522a3c3"},
    {"path": "crates/oce-api/tests/replay_codec.rs", "sha256": "b99c7c05cd1f51392f551fec8fd7f7a9a58d3fa3a518ac364494e35fb53310b8"},
    {"path": "crates/oce-api/tests/release_fallback.rs", "sha256": "85fb1436bf199f650437786b7b33f2235a8be45f46c80683f6230d071df74e4b"},
    {"path": "scripts/release_compatibility/test_check.py", "sha256": "8da906453654ad9cff33a5985a9ad060153a9f37d849c26144d4a4ad054e5374"},
    {"path": "crates/oce-api/tests/release_compatibility.rs", "sha256": "03d7ec40212d2bab1fcfca9548ba099d77ede9b30cc3483c64150528781f7815"},
    {"path": "crates/oce-conformance/tests/strict_bits/matrix.rs", "sha256": "b393a049a95ae3659f4ee7ccb0cb71413220bf9229795640947fcc50a2a4fc72"},
    {"path": "crates/oce-conformance/tests/fixtures/strict_bits/receipts.json", "sha256": "56ca2a8a989cd240f688e556bcb29f9aa5e5f4f934250f607af4ecbd52e62f4d"}
  ]
}