State continuation and portability contract

Authority and scope

This is the execution-maintainer contract for same-loaded-executable continuation (PC-038 in the product contract). It is a pre-release supported boundary, not a cross-release migration promise. OCE is synchronous, in-process and database-free. It captures bytes, not durable storage, a replay log or permission to command equipment.

The separate canonical replay record describes one accepted frame. Optional start/end snapshot bytes remain sidecars in the host’s authenticated ordered envelope; they are not embedded in a record. Replay reuses this placement policy without exposing or relabeling the private execution fingerprint as build authority. Neither snapshot format nor execution ABI changes for replay.

The release-candidate matrix and fallback guide support current/current only, with no N-1 support or cross-build state migration. The historical v0.1.0 source pin has no snapshot API; its absence is not the revision-1 wire refusal described below.

“Same-build” is a mandatory host-envelope precondition, not an OCE comparison. Before calling EngineStateSnapshot::from_bytes, the host authenticates a sealed envelope binding the exact snapshot bytes to its approved compiled-build/deployment qualifier and checks freshness and generation. That qualifier can cover source/dependency lock, compiler, features, target and codegen qualification. OCE emits, accepts, stores and enforces no build token. Pass only the OCE snapshot bytes after approval. A compatible manifest from a differently compiled implementation can pass OCE checks; that is not build qualification. See the restart checklist.

CompatibilityDescriptor, package version, catalog metadata tag, diagnostic model ID and complete export tag are not substitutes for either the host envelope or the state manifest. No universal identity is introduced. Differences in unused catalog entries do not affect this executable; changes to implementation code with unchanged descriptors belong to host build qualification.

Capture, parse and restore

OperationContract
checkpointOwned process-local image; compatible restore can rewind. No persistence format or external authority.
state_snapshotValidate loaded state, stable authored identities and registered state contracts; encode and run the bounded canonical decoder before returning. Every success can be parsed by this build. No evaluation or Store calls.
from_bytesValidate wire structure and manifest self-consistency, not compatibility with a loaded target or every class-specific state invariant. Unknown execution ABI can parse but cannot restore.
restore_stateCheck readiness, target domain, execution ABI, full manifest/fingerprint and payload before one in-memory commit. No evaluation or Store calls.
restore_checkpointSame prepare/commit discipline, without the startup-window restriction. Not a durable-byte bypass.

A successful load opens the durable restore window. Accepted frame execution, dirty-parameter resume, or either successful restore closes it. Snapshot/checkpoint capture, read-only inspection, frame preparation, refused operations, halt and clean resume do not close it. A successful reload opens a new window; an ordinary failed reload preserves the prior one. Pending parameter edits refuse capture and restore before any window check. Restore preserves the current parameter-edit mode, model identity, IO metadata, admission policy, private frame incarnation and Engine-lifetime accepted-frame sequence. It replaces connector values, state words, absolute model time and the prior-time guard only. A preprepared frame still rechecks time at execution. Retained completed frames remain immutable and are not restored or reissued.

All returned restore errors precede mutation and preserve both engine state and Store state. Panic, allocation failure, process termination and external host effects are outside this guarantee. Capture/restore do not create a Store transaction. A later delivery failure cannot undo a frame. At restored time, another accepted frame is another HostTick transition, not event iteration.

Compatibility and deterministic refusal

OCE compares complete structures, not just a collision-prone fingerprint. Incompatible structural catalog/profile/executable/IO/state/target facts refuse at parse or restore as follows:

Check / first-cause orderTyped evidence
Supplied bytes above 64 MiB, before header inspectionSnapshotTooLarge with actual and maximum counts
Short/invalid header; unsupported format; inconsistent total lengthMalformedSnapshot / UnsupportedFormat
Corrupted body/trailer after valid header and lengthIntegrityMismatch with computed and carried checksums
Invalid tags/UTF-8/counts, duplicate or unordered sections, inconsistent references, fingerprint, flags or payload shapeMalformedSnapshot with deterministic offset/detail
Restore without a successful load; pending edits; advanced durable targetNoLoadedModel, PendingParameterEdits, DurableTargetAdvanced, in that order
Foreign target-bound architecture or OSTargetDomainMismatch before execution compatibility
Different execution-state ABI, including a different transition profileIncompatibleExecution, subject execution-state ABI revision
Different manifestIncompatibleExecution, first named subject in the order below
Wrong fingerprint or connector mapping after matching manifestIncompatibleExecution
Invalid initialized/pre-first-tick words, clock relationship or class-specific stateInvalidBlockState
Missing stable authored identities or registered state contract during capture/target constructionIneligibleModel

Manifest comparison order is portability; referenced enum paths and ordered members; blocks by canonical key (key, canonical class, algebraic/stateful kind, state revision/length, raw parameter names and bit-exact typed values, ordered input/output bindings); connectors (key, path, declaration order, native type, computation unit and quantity); connections; block schedule; connector schedule; driver map; state-slot offsets/lengths; external input keys; boundary output identities/bindings; then canonical complete-frame input definitions (path, native type and effective min/max).

The input definitions include the intersection of declaration and all fan-out target bounds, with exact Integer/enum values and Real bits. They are the actual acceptance domain, not lossy PointStore bounds. Unit/quantity changes affect host interpretation and refuse. Display units and other non-executing presentation metadata are not compatibility determinants. Model ID is diagnostic only; changing it alone does not refuse. Parameter edits need a compatible newly loaded target.

Typed variants and structured fields are the host action seam; human-readable subject/detail text is deterministic diagnostic evidence, not a second versioned machine protocol. Hostile text in restore incompatibility/state diagnostics is bounded. Do not match error prose to authorize a build.

Wire revision and integrity

Current format revision 2 / execution-state ABI revision 2 retains fixed HostTick v1. Revision 2 adds connector computation unit/quantity and effective input definitions. Revision-1 bytes lacked those compatibility determinants and now return UnsupportedFormat { revision: 1 }. There is no fallback, silent upgrade or migration. Rollback uses the prior qualified build and its own authenticated state, or a host-approved cold start—not a header edit.

The byte cap is 67,108,864 inclusive. Integers and Real/state words are little-endian; Real payloads preserve all bits, including signed zero and NaN payloads. Strings are length-prefixed UTF-8. Compound keys sort by complete encoded key bytes (including little-endian lengths/indices), not Rust numeric or natural string ordering. Named parameter and input-definition paths use UTF-8 lexical order. Schedules and state-slot layout retain execution order/offsets; they are not freely permutable. Connection vector order is canonicalized; duplicate connections are noncanonical.

The fixed header is OCESTAT\0, u32 format, u32 execution ABI, u64 body length. The body contains u128 execution fingerprint, model ID, model time bits, optional prior-time bits, length-prefixed manifest, keyed connector values, state words and zero reserved flags. A 16-byte trailer follows. Revision-2 connector records append optional unit and quantity (0 = absent; 1 plus string = present). After boundary outputs, the manifest appends a u32 input-definition count; each entry is path, native type, optional typed min and optional typed max (0 = absent; 1 plus value = present).

Both fingerprint and trailer use FNV-1a-128: offset 0x6c62272e07bb014262b821756295c58d, XOR each byte and multiply by 0x0000000001000000000000000000013b modulo 2^128. The fingerprint covers little-endian execution ABI followed by canonical manifest bytes. The trailer covers all preceding snapshot bytes. These are accidental-corruption checks, not cryptographic authenticity, freshness or adversarial collision protection. Recomputing both can produce well-formed forged bytes. Host authentication binds exact bytes, not these FNV values.

The decoder bounds counts, lengths and charged allocation workspace; the byte cap is not a process peak-memory or CPU deadline guarantee. Capture also bears encoding/decoding allocation costs; it is not an allocation-free hot-path operation. OCE owns no filesystem. Truncation tests model partial durable bytes, not device power-loss resilience or atomic file publication.

Portability domains and evidence limits

EngineStateSnapshot::portability() returns a borrowed, cloneable StatePortability:

PolicyPlacement checkEvidence boundary
PortableNo architecture/OS restriction in the current class policy; all other checks still apply.Native Linux x86_64/aarch64 debug/release CI compares a populated portable state vector. This is bounded execution evidence, not every input/program/target.
TargetBound { arch, os }Exact capture architecture and OS labels required.CI compares same-target debug/release bytes, requires cross-architecture bytes to differ, and exercises foreign-target public restore refusal. Same target does not mean same build.

Inspection is not admission: an unknown execution ABI may expose a parsed placement tag but still refuses restore. Hosts keep encoded bytes intact and never rewrite the tag to move state.

The conservative target-bound set remains exactly 15 classes: CDL.Reals.Acos, Asin, Atan, Atan2, Cos, Exp, Log, Log10, Sin, Tan (each under CDL.Reals); CDL.Reals.Sources.Sin; CDL.Psychrometrics.DewPoint_TDryBulPhi, SpecificEnthalpy_TDryBulPhi, WetBulb_TDryBulPhi (each under CDL.Psychrometrics); and CDL.Utilities.SunRiseSet. Any participating target-bound class binds the executable.

The accepted strict-bit receipt covers only 21 Linux signal cases on pinned rustc/libm, four native architecture/codegen cells and a selected 35-file source boundary. It is not a full compiled dependency closure, arbitrary-input guarantee, mathematical oracle or macOS qualification. It therefore does not relax this state-placement policy. Local macOS passing tests do not supply the hosted Linux evidence or broaden either variant’s claim.

Continuation of published Library rules

tests/library_rule_state_continuation.rs runs two fault rules from open-control-library through the durable path exactly as a host would: state_snapshot, a host-envelope approval stand-in, EngineStateSnapshot::from_bytes, a freshly loaded engine and restore_state inside the startup window. The CXF graphs and vectors are unedited copies (tests/fixtures/library_rules/):

  • AHU-0016 (simultaneous heating and cooling): a Logical.TrueDelay persistence timer of 900 s.
  • AHU-0004 (excessive operating-state changes): Integers.Change, a 3600 s Reals.MovingAverage window and a 3600 s Logical.TrueDelay.

For all 16 scenarios, a restart after load and after every tick, and a chained restart after every tick, reproduce the uninterrupted run bit for bit: every boundary and internal output, and the full canonical state bytes. Named restarts land mid-dwell (AHU-0016 at 480 s, half way through the delay) and inside partly filled or draining windows (AHU-0004 at 900, 1800, 7800 and 11400 s); a cold start at the same point diverges in every case, so the restored state is load-bearing. The uninterrupted run also meets every Library expectation window. No block in either rule loses state across a restart.

Restore continues model time; it does not decide what a gap in that time means. If the first frame after a restart arrives later than one tick after the snapshot, the restored blocks treat the gap as elapsed time: a satisfied TrueDelay counts the outage toward its delay, and MovingAverage integrates the first post-restart input over the whole gap (with AHU-0004, one state change seen across a one-hour gap reads as twelve). The same frames would do the same in an engine that never restarted. Choosing the resume time, and whether an outage is a gap, a cold start or a host NO_EVAL window, is host frame policy.

Evidence map

  • tests/state_contract.rs: public inspection, changed bounds/units/quantities, historical wire refusal and signed-zero/equal-time continuation against a hand-derived Boolean recurrence.
  • src/tests/state_manifest_refusal_tests.rs: rechecksummed field mutation corpus, repeat typed diagnostics, full snapshot/checkpoint before/after images, retained lifecycle fences and Store noninterference; capture refuses a deliberately injected noncanonical producer image.
  • src/tests/state_format_golden_tests.rs, state_tests.rs, state_io.rs: independent full codec construction, checked byte/fingerprint goldens and hand-assembled domain encoding.
  • src/tests/state_codec_tests.rs, state_resource_tests.rs, state_restore_validation_tests.rs: every truncation boundary, checksum/length/tag hostility, exact cap and one-past, block-state refusals and decode/capture resource checks.
  • src/tests/state_portability_tests.rs: all 15 actual target-bound class captures, independent arch/OS refusals, and artifacts consumed by the unchanged hosted state matrix.
  • tests/library_rule_state_continuation.rs: durable restart of two unedited Library fault rules (persistence timer, moving window) at every tick, chained and mid-dwell, against an uninterrupted run, with cold-start divergence controls and typed refusals on advanced or foreign targets.
  • Existing continuation, family, lifecycle and Pre suites retain complete-frame continuation and current warning/state semantics. These tests qualify OCE boundaries, never host compliance.