Source code for bac_py.transport.foreign_device6

"""Foreign device registration manager for BACnet/IPv6 per Annex U.

Provides ForeignDevice6Manager for registering with a remote IPv6 BBMD,
periodic re-registration, and broadcast distribution via the BBMD.
"""

from __future__ import annotations

import asyncio
import contextlib
import logging
from typing import TYPE_CHECKING

from bac_py.transport.bvll_ipv6 import encode_bvll6
from bac_py.types.enums import Bvlc6Function, Bvlc6ResultCode

if TYPE_CHECKING:
    from collections.abc import Callable

    from bac_py.network.address import BIP6Address

logger = logging.getLogger(__name__)


[docs] class ForeignDevice6Manager: r"""Manages registration with a remote IPv6 BBMD per Annex U. A BACnet/IPv6 device on a different subnet registers with a BBMD as a "foreign device" to receive broadcast traffic. This manager handles: - Initial registration with the BBMD - Periodic re-registration at TTL/2 intervals to prevent expiry - Tracking registration state (registered, failed) - Sending broadcasts via Distribute-Broadcast-NPDU Usage:: fd_mgr = ForeignDevice6Manager( bbmd_address=BIP6Address("fd00::1", 47808), ttl=60, send_callback=transport_send, local_vmac=b"\x01\x02\x03", ) await fd_mgr.start() # ...later... await fd_mgr.stop() """ def __init__( self, bbmd_address: BIP6Address, ttl: int, send_callback: Callable[[bytes, BIP6Address], None], local_vmac: bytes, local_address: BIP6Address | None = None, ) -> None: """Initialize IPv6 foreign device manager. :param bbmd_address: B/IPv6 address of the BBMD to register with. :param ttl: Time-to-Live in seconds for registration. :param send_callback: Called with ``(raw_bytes, destination)`` to send a UDP datagram. :param local_vmac: 3-byte VMAC for source_vmac in all BVLL6 messages. :param local_address: This device's B/IPv6 address. Required for sending deregistration on stop. """ self._bbmd_address = bbmd_address if ttl < 1: msg = f"TTL must be >= 1 second, got {ttl}" raise ValueError(msg) self._ttl = ttl self._send = send_callback self._local_vmac = local_vmac self._local_address = local_address self._task: asyncio.Task[None] | None = None self._registered = asyncio.Event() self._last_result: Bvlc6ResultCode | None = None # Pre-compute registration BVLL6 (payload is always the same) self._registration_bvll = encode_bvll6( Bvlc6Function.REGISTER_FOREIGN_DEVICE, self._ttl.to_bytes(2, "big"), source_vmac=self._local_vmac, ) @property def bbmd_address(self) -> BIP6Address: """The BBMD address this device is registered with.""" return self._bbmd_address @property def ttl(self) -> int: """The registration TTL in seconds.""" return self._ttl @property def is_registered(self) -> bool: """Whether the device is currently registered with the BBMD.""" return self._registered.is_set() @property def last_result(self) -> Bvlc6ResultCode | None: """The last BVLC6-Result code received from the BBMD.""" return self._last_result
[docs] async def start(self) -> None: """Start the registration loop. Sends an initial registration and begins periodic re-registration at TTL/2 intervals. """ if self._task is not None: return self._task = asyncio.create_task(self._registration_loop())
[docs] async def stop(self) -> None: """Stop the registration loop and deregister from the BBMD. If the device is currently registered and a local address was provided, sends a Delete-Foreign-Device-Table-Entry to the BBMD so it can immediately remove the FDT entry. """ if self._task is not None: self._task.cancel() with contextlib.suppress(asyncio.CancelledError): await self._task self._task = None if self._registered.is_set(): self._send_deregistration() self._registered.clear()
[docs] def handle_bvlc_result(self, data: bytes) -> None: """Process a BVLC6-Result received from the BBMD. :param data: 2-octet result code payload. """ if len(data) < 2: return result_code = Bvlc6ResultCode(int.from_bytes(data[0:2], "big")) self._last_result = result_code if result_code == Bvlc6ResultCode.SUCCESSFUL_COMPLETION: if not self._registered.is_set(): logger.info( "Registered as IPv6 foreign device with BBMD [%s]:%d (TTL=%ds)", self._bbmd_address.host, self._bbmd_address.port, self._ttl, ) self._registered.set() else: logger.warning( "IPv6 foreign device registration NAK from BBMD [%s]:%d: %s", self._bbmd_address.host, self._bbmd_address.port, result_code.name, ) self._registered.clear()
[docs] def send_distribute_broadcast(self, npdu: bytes) -> None: """Send a broadcast via the BBMD using Distribute-Broadcast-NPDU. This is used by foreign devices instead of multicast broadcast. The BBMD will distribute the NPDU to all BDT peers and other registered foreign devices. :param npdu: NPDU bytes to broadcast. :raises RuntimeError: If not registered with a BBMD. """ if not self._registered.is_set(): msg = "Not registered as an IPv6 foreign device" raise RuntimeError(msg) bvll = encode_bvll6( Bvlc6Function.DISTRIBUTE_BROADCAST_NPDU, npdu, source_vmac=self._local_vmac ) self._send(bvll, self._bbmd_address)
def _send_registration(self) -> None: """Send a Register-Foreign-Device message to the BBMD.""" self._send(self._registration_bvll, self._bbmd_address) logger.debug( "Sent Register-Foreign-Device to [%s]:%d (TTL=%ds)", self._bbmd_address.host, self._bbmd_address.port, self._ttl, ) def _send_deregistration(self) -> None: """Send a Delete-Foreign-Device-Table-Entry for this device.""" if self._local_address is None: return payload = self._local_address.encode() bvll = encode_bvll6( Bvlc6Function.DELETE_FOREIGN_DEVICE_TABLE_ENTRY, payload, source_vmac=self._local_vmac, ) self._send(bvll, self._bbmd_address) logger.info( "Sent Delete-Foreign-Device-Table-Entry to [%s]:%d", self._bbmd_address.host, self._bbmd_address.port, ) async def _registration_loop(self) -> None: """Re-register at TTL/2 intervals per Annex U.""" while True: try: self._send_registration() except OSError: logger.warning("Failed to send IPv6 foreign device registration", exc_info=True) await asyncio.sleep(self._ttl / 2)