This intentional pre-release source break removes legacy execution profiles as well as the earlier speculative facade shapes. Nothing is published to crates.io; no stable SemVer or downstream compatibility certification is implied. The public surface contract and its exact baseline own classification.

Removed names and working alternatives

RemovedHost action
Engine::load_modelicaPrepare already-specialized, supported CXF externally, then use load_cxf. OCE does not parse Modelica source.
Engine::load_from_semantic, TemplateRefRemove speculative loader calls. There is no semantic-template loader replacement; an app can prepare supported CXF itself. The active effective-point metadata resolver is unrelated and remains wired.
Flat oce_api::SemanticQueryFor conditional adapter queries, use oce_api::oce_store::SemanticQuery or direct oce_store::SemanticQuery. Those types/traits are unchanged; this does not supply a template loader.
InputSource and its variants, SimSpec, CollectSpec, SimMetrics, OutputTraceDecode tables and drive a host-owned loop of complete frames. There is no implicit restart, input callback or facade trace collector. Conformance reference-table replay remains host-side.
Engine::tick, tick_with, set_input, simulate, step_realtimeCollect every required input once, call prepare_frame, then move the result into execute_frame. Missing/duplicate/domain-invalid input refuses before mutation. No compatibility aliases exist.
Realtime epoch accessors and realtime-only error variants, StepReportOwn wall-clock mapping, persistence and delivery outside execution; realtime/Store orchestration is deferred. No engine write-back helper replaces them.
Outputs, Engine::outputsRetain CompletedFrame for committed boundary results and warnings. Use get_output/watch only for explicitly latest-state, non-receipt inspection.
AssertLevel::ErrorUpdate exhaustive matches and code that constructed the unimplemented severity. AssertLevel now contains only Warning; AssertEvent.level remains.

Default-value change: AssertLevel::default() is now Warning, previously Error. A signature baseline cannot detect this value change, so a separate explicit default golden pins it. This is not new escalation, abort behavior or safety logic. Actual CDL.Utilities.Assert CXF tests check true is silent, false produces repeated Warning events, exact message/source/time bits, continued execution and repeat-run equality. Expected files are hand-derived from Boolean assertion semantics and the HostTick reporting contract, not an external solver trace. The emitted source is currently the class path CDL.Utilities.Assert, not an instance identity. Every accepted frame retains its warnings; execution does not perform an external write or acquire a post-write failure mode.

Inventory and execution boundaries remain

point_list(None) keeps its existing signature and returns the engine’s own effective inventory. Device filtering (Some, including empty/unknown strings) is outside the supported profile and returns the existing OcError::Load directly. No new Unsupported variant exists and no store query is delegated, even with a capable adapter. This is not an experimental supported feature. The custom-adapter regression checks the None result, specific refusal, no store calls and no engine mutation. Existing error detail text is retained for compatibility, not promoted into an API schema.

Load/store side effects still precede engine-field commit; only the in-memory executable/run image has the replacement guarantee. Frame refusal preserves the current run. Consecutive frames continue state; fresh loads and explicit compatible checkpoint restores are distinct lifecycle operations. State-wire bytes, independent numerical goldens, catalog identity, HostTick arithmetic and engine thread-safety remain unchanged.

Package and panic-inventory boundary

No package/feature/dependency policy changes: 17 members, 12 publishable, five private; all three supported feature selections retain the same eleven normal OCE dependencies and the mem no-op. Private oce-docs retains its point_list_html unimplemented exporter outside the supported closure. Private oce-extension retains its reserved DTO, with no runtime. oce-flatten successfully returns its input model unchanged, and oce-semantics actively derives effective point metadata; both remain wired implementation dependencies. No new feature or replacement placeholder is introduced.

The focused production inventory distinguishes placeholder handlers from invariant checks: CXF resolver composite.rs and composite_orientation/diagnostics.rs contain unreachable! arms after exhausting the two traversal-frame variants. Blocks’ timetable/controller token mappings contain invariant arms over repository-owned constants. Snapshot decoding’s bounds-checked expects, debug assertions and test-helper panics are not deferred feature handlers. None were purged. Typed hostile-input tests bound the exercised paths; there is no universal panic-free, adapter-panic, cancellation or equipment-safety claim.

Compatibility evidence limits

The compiler contract checks retired names plus same-dependency frame controls under default, explicit mem and no-default selections. Baseline reintroduction controls are additional, not a substitute for compilation; unrelated associated Error types remain in the baseline. Only the facade baseline changes (2384 to 2111 rows for this contraction); the storage baseline remains byte-identical.

Prior downstream inspection is dated inventory, not compatibility with the frame-only facade. Actual downstream pins are unchanged. Exact-candidate Studio adapter and Library verifier fixture compilation is separate pre-delivery qualification, not established by that inspection or by the in-repository compiler controls. No downstream acceptance or pin advance is claimed here.

Additive contract adoption

The versioned facade contracts add typed oce_api::catalog() metadata, canonical catalog JSON/content identity and seven packaged shape/semantic descriptors. A new consumer can adapt every rule/default/port field using only oce-api. Existing oce-blocks companion users retain their current surface; coordinated removal and downstream pin migration remain later work. Existing state/ABI/catalogue fingerprints and HostTick behavior are unchanged.

For producer-stage evidence, opt into load_cxf_with_receipt and export_cxf_with_receipt. Success receipts expose the existing report and independently captured immutable diagnostics; into_parts permits legacy report mutation without corrupting evidence. Failures expose terminal stage, complete returned diagnostics and original OcError/standard source context. Compare DiagnosticKey values for the new machine ordering; retain the old methods when legacy ordering is required. Messages are display-only, code strings extensible, subjects opaque or absent, and multiplicity preserved. Diagnostic-free failures remain failures without fabricated codes.

Studio continues to own full build/source/features compatibility stamps, catalog display policy, truncation and authored-target mapping. OCE’s metadata content tag supplies none of those policies. No source/pin is advanced in a real consuming repository. Existing load/export signatures and reports remain. The assertion and execution descriptor revisions advance to 2 to describe the frame-only boundary; this is not a new HostTick profile, catalog identity or snapshot format.

Bounded serialized load adoption

Existing load signatures remain. Both raw load_cxf and load_cxf_with_receipt now refuse byte slices above 8 MiB before deserialization, with the additive OcError::CxfTooLarge containing actual_bytes and limit_bytes only. The receipt stage is Import; diagnostic order and sources below the cap remain unchanged. Inputs formerly accepted above the cap are deliberately no longer supported; widening is not an escape hatch. Hosts retain transport caps and trust isolation.

Read the effective policy with Engine::cxf_byte_limit() and optionally set a smaller value with set_cxf_byte_limit(bytes). The inclusive allowed range is 0..=MAX_CXF_BYTES; values above it return the typed OcError::CxfByteLimitTooLarge, leaving the engine unchanged. Configuration is per-engine, may be changed within that range, persists across reload and is not encoded in snapshots.

Failed ordinary reloads preserve the old in-memory run image, but Store effects are not rolled back and old external handles may no longer be valid. Plan adapter compensation before continuing control. Successful reload requires refreshing model-local IDs, IO views and other ephemeral references as before. No Store trait, catalog/descriptor identity, state bytes, HostTick, package or dependency changes accompany admission. No downstream source or pin migration is performed here.

Compatibility receipt adoption

The additive closed descriptor does not replace existing receipts or alter their bytes. Migrate only the public-fact comparison portion:

Current receipt field/useMapping
LoadReport.model_id / load receipt reportKeep for authored/synthetic diagnostic correlation. Never pass it as export, executable or compatibility identity.
catalog_content_id(catalog())Same text at descriptor.catalog_content_id().as_str(), now category-typed. Caller-edited catalog DTOs are not the current engine catalog descriptor.
IO/value/parameter contract_descriptors() revisionsSame revisions through the descriptor’s named schema accessors. Still metadata contracts, not model input-definition identity.
Fixed HostTick profile and descriptorexecution_profile() is HostTick-v1; execution_profile_schema_revision() remains the existing revision 2.
Host source/build/features stampRetain it. oce_api_version() adds only the exact OCE Cargo package version, not a unique build fingerprint.
ExportReport::content_id_complete() / export receipt reportPass Some(report) to CompatibilityDescriptor::current; its completeness check remains the sole minting path. Preserve typed refusal on warnings.
No export availablePass None; the canonical receipt records export:none, which never matches present content.
Checkpoint/snapshot or frame receiptNo replacement. Existing restore checks and frame lifecycle remain authoritative; descriptor agreement authorizes neither replay nor restore.

Retain the owned descriptor or its canonical to_string() bytes. Compare in-memory descriptors with check_compatible; store canonical bytes and compare exactly when using persisted receipts. No OCE parser, source normalizer, external attestation or signature authority is introduced. Legacy export reports are host-mutable, so capture before edits if producer-returned content is intended. Capture again after re-export to describe parameter edits. Same-byte reload may keep the descriptor equal while invalidating prepared plans: this is deliberately not a generation fence. No actual downstream pin or source is changed or qualified here.